Insulating Gloves
Products » Electrical Safety
Extreme Safety are the sole importers for the extremely high quality KCL electrical insulating gloves manufactured in Europe. These gloves comply with all relevant European Standards (EN 60903 - Insulating Gloves for Working with Electricity) that are accepted worldwide, including Australia. KCL Insulating Gloves are also the ONLY gloves available worldwide that have been tested to, and PASSED, arc and flashover tests. Despite being rubber gloves, they do not melt, and will provide protection to the wearer's hands in the event of an electric arc.
Extreme Safety has insulating gloves manufactured from a type of natural latex from Class 00 up to Class 3. This equates to gloves suitable from work up to 500V, in the form of the Class 00 gloves, up to gloves for use up to 26,500V, in the Class 3 glove.
| Class | Working Voltage |
|---|---|
| 00 | 500V |
| 0 | 1000V |
| 1 | 7500V |
| 2 | 17000V |
| 3 | 26500V |
All gloves in the range are 410mm in length. This excludes the class 00, or 500V glove which is available in two versions, short (290mm) or long (360mm).
The different working voltage for the gloves is determined by the specifically designed wall thickness; with a higher voltage, a thicker glove is required. For example a Class 00 glove is 0.5mm in thickness, the common 1000V, Class 0 glove is 1mm thick, while a 26500V Class 3 glove has a wall thickness of 2.9mm.
The gloves are available in 3 different sizes to ensure the optimum fit and therefore dexterity, size 9, 10 and 11. These gloves, like all electrical insulating on the market gloves do not have overly confidence inspiring puncture resistance figures. For this reason it is recommended that a leather outer glove, also available from Extreme Safety be worn for mechanical protection. Extreme Safety offers four options of outer gloves cow, kangaroo, goat and sheep skin. Kangaroo and Goat are slightly stronger and harder wearing but does not provide as good feel as sheep, which is finer leather, however is not as wear resistant. For more information visit the Leather Outer Gloves page.
Extreme Safety also tests electrical insulating gloves and other PPE electrically insulated products in-house. Extreme Safety are also obliged to advise that this MANDATORY that equipment be tested every 6 months from the date put into service. Using gloves that are out of test date may carry severe penalties and fines. Please contact us for further information on our testing service.
| Item Code | Description |
|---|---|
| 0582/Size | Insulating Gloves Class 00 Short - Size 9 - 11 |
| 0583/Size | Insulating Gloves Class 00 Long - Size 8 - 11 |
| 0584/Size | Insulating Gloves Class 0 - Size 8 - 11 |
| 0585/Size | Insulating Gloves Class 1 - Size 9 - 11 |
| 0586/Size | Insulating Gloves Class 2 - Size 9 - 11 |
| 0587/Size | Insulating Gloves Class 3 - Size 9 - 11 |
Product Specifications
| Item No. | 0582 | 0583 | 0584 | 0585 | 0586 | 0587 |
|---|---|---|---|---|---|---|
| Designation | Electro | Electro | Electro | Electro | Electro | Electro |
| Colour | red | red | red | red | red | red |
| Material | natural latex | natural latex | natural latex | natural latex | natural latex | natural latex |
| Design | without rolled edge | without rolled edge | without rolled edge | without rolled edge | without rolled edge | without rolled edge |
| Class | 00 | 00 | 0 | 1 | 2 | 3 |
| Length (mm) | 290 ± 15 | 360 ± 15 | 410 ± 15 | 410 ± 15 | 410 ± 15 | 410 ± 15 |
| Thickness (mm) | max. 0.5 +0.6 | max. 0.5 +0.6 | max. 1 +0.6 | max. 1.5 +0.6 | max. 2.3 +0.6 | max. 2.9 +0.6 |
| Sizes | 09 - 11 | 08 - 11 | 08 - 11 | 09 - 11 | 09 - 11 | 09 - 11 |
| Packing unit per size | 1 pair | 1 pair | 1 pair | 1 pair | 1 pair | 1 pair |
Physical Data Decisive for the Mechanical Stress and Wearing Comfort
| Tensile strength EN 60903 | >= 20 MPa | >= 20 MPa | >= 20 MPa | >= 20 MPa | >= 20 MPa | > =20 MPa |
|---|---|---|---|---|---|---|
| Elongation at break EN 60903 | >= 600 % | >= 600 % | >= 600 % | >= 600 % | >= 600 % | >= 600 % |
| Mechanical puncture resistance EN 60903 | >= 30 N/mm | >= 30 N/mm | >= 30 N/mm | >= 30 N/mm | >= 30 N/mm | >= 30 N/mm |
| Tension rest EN 60903 | <= 7 % | <= 7 % | <= 7 % | <= 7 % | <= 7 % | <= 7 % |
| Ozone resistance | very good | very good | very good | very good | very good | very good |
| Low temp. flexibility | very good (max. appr. -40ºC) |
very good (max. appr. -40ºC) |
very good (max. appr. -40ºC) |
very good (max. appr. -40ºC) |
very good (max. appr. -40ºC) |
very good (max. appr. -40ºC) |
| High temp. resistance | low (max. 90ºC) | low (max. 90ºC) | low (max. 90ºC) | low (max. 90ºC) | low (max. 90ºC) | low (max. 90ºC) |
Electric Tension Strength
| Test Voltage (kv) AC | 2.5 | 2.5 | 5 | 10 | 20 | 30 |
|---|---|---|---|---|---|---|
| Leakage current (mA) | max. 14 | max. 14 | max. 16 | max. 16 | max. 16 | max. 16 |
| Working voltage (kv) | max. 0.5 | max. 0.5 | max. 1 | max. 7.5 | max. 17 | max. 26.5 |




